Description
TECHNICAL SPECIFICATIONS
INPUT | |
---|---|
Capacity | 2000/1200 |
Nominal Input Voltage |
110/120Vac or 220/230/240 Vac |
Operating Voltage Range | 81-145Vac/162-290 Vac |
Operating Frequency Range | 60/50 (Auto sensing) |
OUTPUT | |
---|---|
AC Voltage Regulation (Batt. Mode) | ±10% |
Frequency Range (Batt. Mode) (Hz) | 60/50 ±1 |
Transfer Time (ms) | Typical 2-6, 10 Max. |
Waveform (Batt. Mode) | Simulated Sinewave |
BATTERY | |
---|---|
Voltage (Vdc) | 24 |
Typical Recharge Time (hours) | 6-8 recover to 90%Â capacity |
Capacity (Ah) & Number (pcs) | 9 x 2 |
MANAGEMENT | |
---|---|
LED Display | AC Mode, Battery Mode, Overload, Fault |
LCD Display | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low |
Alarm | Battery mode, Battery low, overload, Battery replacement, Fault |
Communication Port | USB or RS232 (Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC) |
MANAGEMENT | |
---|---|
LED Display | AC Mode, Battery Mode, Overload, Fault |
LCD Display | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low |
Alarm | Battery mode, Battery low, overload, Battery replacement, Fault |
Communication Port | USB or RS232 (Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC) |
PROTECTION | |
---|---|
Full Protection | Short circuit, Overload , Overcharge and overdischarge protection |
ENVIRONMENTAL | |
---|---|
Humidity | 0~90%RH @ 0~40℃ (Non condensing) |
Noise Level (dB) | <55 |
PHYSICAL | |
---|---|
Dimension WxDxH (mm) | 380×158×198 |
Weight (kg) | 10.5 |
Reviews
There are no reviews yet.